Step 1. Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server. Then, take the new part out of the package and place it on a static-protective
surface.
Step 2. Install the supercap holder if you have removed.
Figure 167. Supercap holder installation
a. Align the keyhole on the supercap holder with the pin on the chassis, and lower the supercap
holder into the chassis.
b. Slide the supercap holder in the shown direction until it clicks into place.
Step 3. Install the RAID flash power module.
Figure 168. RAID flash power module installation
a.
Insert the RAID flash power module into the retaining clip at one side as shown.
Chapter 5. Hardware replacement procedures 201