EasyManua.ls Logo

Lenovo ThinkSystem SR650 V3 7D75 - Page 241

Lenovo ThinkSystem SR650 V3 7D75
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A video of this procedure is available at YouTube: https://www.youtube.com/playlist?list=PLYV5R7hVcs-
BmyijyY0-lNvapM4fTV5Gf
.
Procedure
Step 1. Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server. Then, take the new part out of the package and place it on a static-protective
surface.
Step 2. Connect cables to the drive backplane. See
Chapter 6 “Internal cable routing” on page 271.
Step 3. Install the drive backplane into the rear drive cage.
Figure 203. Installing the 2 x 3.5-inch rear drive backplane
a. Align the bottom of the backplane with the studs at the bottom of the drive cage.
b. Lower the backplane into the drive cage so that the holes in the backplane pass through the
pins on the drive cage, and press the backplane into position.
Step 4. Install the rear drive cage.
Chapter 5. Hardware replacement procedures 231

Table of Contents

Related product manuals