Parameters:
[arg1] Cpu Silk screen label, 1-based
User Action:
Complete the following steps:
1. Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this
error.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFIO0042N: An uncorrectable USB error (Type [arg1]) is detected on processor [arg2] USB
controller [arg3].
Severity: Error
Parameters:
[arg1] TxFIFO/RxFIFO
[arg2] Cpu Silk Label, 1-based
[arg3] USB controller number, 0-based
User Action:
Complete the following steps:
1. Check the Lenovo Support site for an applicable service bulletin or UEFI firmware update that applies
to this error.
2. Remove all the connected USB devices connected to the USB controller according to system spec
and reboot the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0001I: DIMM [arg1] Disable has been recovered. [arg2]
Severity: Info
Parameters:
[arg1] DIMM slot silk label
[arg2] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Information only; no action is required.
• FQXSFMA0001M: DIMM [arg1] has been disabled due to an error detected during POST. [arg2]
Severity: Error
Parameters:
[arg1] DIMM slot silk label
[arg2] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
174