Service Action:
Information only; no action is required.
• FQXSFMA0015I: Memory spare copy has completed successfully. [arg1]
Severity: Info
User Action:
Check system log for related DIMM failures and replace those DIMMs.
Service Action:
Information only; no action is required.
• FQXSFMA0016M: Memory spare copy failed. [arg1]
Severity: Warning
User Action:
Complete the following steps:
1. Boot to uEFI F1 screen and make sure that all DIMMs are enabled. Reboot the system.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
Service Action:
Complete the following steps:
1. Verify PD steps.
2. Replace the DIMM identified by LightPath and/or event log entry if -V20 is NOT appended to the DIMM Serial
Number in the FFDC event log.
3. Replace system board.
4. If needed, replace processor.
5. If problem persists, escalate to next level support.
• FQXSFMA0023M: Error has occurred in NVDIMM flash. NVDIMM backup/restore may not operate
correctly. [arg1]
Severity: Error
User Action:
Complete the following steps:
1. Reseat the affected NDIMM, and the DIMM in the adjacent slots if populated.
2. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.