If you have no other operations to perform on the I/O tray after installing the riser for slots 10 through 15,
install the I/O tray in the chassis and connect all cables. See “Install the I/O tray” on page 153.
Install a riser bracket for slots 14 and 15
The riser bracket for slots 14 and 15 is attached to the slot 10 through 15 I/O tray riser that is accessed from
the rear of the server. After removing the I/O tray and the riser for slots 10 through 15 (right riser), slide the
bracket onto the riser until the retaining clips engage.
S002
CAUTION:
The power control button on the device and the power switch on the power supply do not turn off the
electrical current that is supplied to the device. The device also might have more than one power
cord. To remove all electrical current from the device, ensure that all power cords are disconnected
from the power source.
Before you install the riser bracket, make sure that there is no filler installed on the I/O tray for slots 14 and
15.
Complete the following steps to install the riser bracket.
Watch the procedure. A video of the installation process is available:
Youtube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-DbSYJFY74PoKmph7vgrkKH&playnext=1
Youku: http://list.youku.com/albumlist/show/id_50952215
Figure 108. Riser bracket installation (slots 14 and 15)
Step 1. Align the slots on the riser bracket with the pins on the riser and slide it in place; then, press the
bracket onto the riser until the retaining clips engage.
If you have no other operations to perform on the riser after installing an adapter in slots 10 through 15:
1. Install adapters in the riser. See “Install a PCIe adapter in slots 10 through 15” on page 120.
Appendix B. Component reference 179