PCI
riser-card
assembly
Slot 3, PCIe3 x8 (8, 4, 1)
Figure33.Slot3
0000000
0000000
0000000
0000000
0000000
0000000
0000000
Figure34.Slot2andSlot1
Note:ThesupportedPCIslotfortheRAIDlinkfunctionisslot2and3.However,pleasenotewheninstalling
RAIDcontrollerM5120,itcanonlybeinstalledinslot1and2.
ToinstallaServeRAIDadapteronthePCIriser-cardassembly,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginsonpage“Safety”onpagevand“Installationguidelines”
onpage30.
Step2.Turnofftheserver(see“Turningofftheserver”onpage19)andallattachedperipheraldevices.
Disconnectallpowercords;then,disconnectallexternalcablesfromtheserver.
Step3.Removethetopcover(see“Removingtheservertopcover”onpage32).
Step4.IfyouareinstallinganeworreplacementServeRAIDadapter,touchthestatic-protectivepackage
thatcontainsthenewServeRAIDadaptertoanyunpaintedmetalsurfaceontheserver.Then,
removetheServeRAIDadapterfromthepackage.
Step5.IfyouareinstallinganeworreplacementServeRAIDadapterthatusesabattery,completethe
followingsteps:
1.RemovethebatteryfromtheServeRAIDadapterpackageorthebatterypackage.
2.InstallthebatteryandconnectthebatterytotheServeRAIDcontrollerasinstructedinthe
documentationthatcomeswiththeServeRAIDcontrollerorthebattery,orsee“Installinga
ServeRAIDadapterbatteryorflashpowermoduleintheremotebatterytray”onpage50.
Step6.ThefollowingillustratesthestepsforinstallingaServeRAIDadapteronthePCIriser-card
assemblies:
Chapter2.Installingoptionaldevices47