Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05 125
7 Drive application
7.1 Parameterisation dialog
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Configuration parameters for analog setpoints:
Display parameter
bRLQCcw
(C701/18)
0: Not connected Activate counter-clockwise rotation (fail-safe)
bSetSpeedCcw
(C701/5)
14: DigIn_bIn4
(DI4)
Change of direction of rotation
bJogSpeed1
(C701/6)
11: DigIn_bIn1
(DI1)
Selection of fixed setpoints (JOG setpoints)
bJogSpeed2
(C701/7)
12: DigIn_bIn2
(DI2)
bPIDEnableInfluenceRamp
(C701/15)
1: C_bTrue L_PCTRL_1: Activate ramp for influencing factor
bPIDOff
(C701/16)
0: Not connected L_PCTRL_1: Switch off I component
bCInh
(C701/1)
1: C_bTrue Enable/Inhibit controller
bFailReset
(C701/2)
15: DigIn_CInh
(RFR)
Reset of error message
bSetQuickstop
(C701/3)
0: Not connected Enable quick stop (QSP)
bSetDCBrake
(C701/3)
13: DigIn_bIn3
(DI3)
Manual DC-injection braking (DCB)
Parameter
Selection of signal source
(Lenze setting)
for setpoint selection:
nMainSetValue_a
(C700/1)
10: AIn1_Out
(Analog input 1)
Main setpoint
• 100 % ≡ reference speed (C011
)
nPIDSetValue_a
(C700/9)
0: Not connected L_PCTRL_1: Sensor setpoint or process setpoint for ope-
rating mode 2
nPIDVpAdapt_a
(C700/6)
1: C_nPos100_a
(100%)
L_PCTRL_1: Adaptation of the gain Vp set in C222 in per-
cent
nPIDActValue_a
(C700/7)
0: Not connected L_PCTRL_1: Actual speed value or actual sensor value
(actual process value)
nPIDInfluence_a
(C700/8)
1: C_nPos100_a
(100%)
L_PCTRL_1: Limitation of the influencing factor in per-
cent
Parameter Info
nIn_a
(C830/11)
Input value of motor potentiometer
nNSet_a
(C830/1)
Input value of setpoint generator
nOut_a
(C830/2)
Output value of setpoint generator
nSpeedSetValue_a
(C830/2)
Speed setpoint for motor control
nSet_a
(C830/8)
Sensor setpoint or process setpoint for operating mode 2
nAdapt_a
(C830/7)
Adaptation of the gain Vp set in C222 in percent
nAct_a
(C830/6)
Speed or actual sensor value (actual process value)
Parameter
Selection of signal source
(Lenze setting)
for control signal: