Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05 131
7 Drive application
7.2 Interface description
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
bCInhActive
BOOL
TRUE Controller inhibit is active
bQSPIsActive
BOOL
TRUE Quick stop is active
bSafeTorqueOff
BOOL
TRUE "SafeTorqueOff" device state is active
bSafetyIsActive
BOOL
TRUE In preparation
bSpeedCcw
BOOL
FALSE Clockwise rotation (Cw)
TRUE Counter-clockwise rotation (Ccw)
bActSpeedEqZero
BOOL
TRUE Current speed is 0
bSpeedSetReached
BOOL
TRUE Speed setpoint reached
bSpeedActEqSet
BOOL
TRUE Actual speed value has reached the setpoint within one hysteresis
band
bNactCompare
BOOL
TRUE During open-loop operation:
Speed setpoint < comparison value (C024
)
During closed-loop operation:
Actual speed value < comparison value (C024
)
bImaxActive
BOOL
TRUE The current setpoint is limited internally
(the controller operates at the maximum current limit)
Motor control
bHeatSinkWarning
BOOL
TRUE Heatsink overtemperature detected
bOVDetected
BOOL
TRUE Overvoltage detected
bDcBrakeOn
BOOL
TRUE DC-injection braking active
bFlyingSyncActive
BOOL
TRUE Flying restart function is executed
nMotorFreqAct_a
C058 | INT
Current field frequency
nOutputSpeedCtrl_a
INT
Speed or slip controller output
Scaling: 16384 100 % reference speed (C011
)
nMotorSpeedAct_a
C051 | INT
Actual speed value
Scaling: 16384 100 % reference speed (C011
)
nMotorVoltage_a
INT
Current motor voltage/inverter output voltage
Scaling: 16384 1000 V
nDCVoltage_a
INT
Actual DC-bus voltage
Scaling: 16384 1000 V
nMotorCurrent_a
INT
Current motor current
Scaling: 16384 100 % I
max_mot
(C022)
nMotorTorqueAct_a
C056/2 | INT
Actual torque
With "VFC (+encoder)" motor control, this value is determined from the current
motor current and corresponds to the actual torque only by approximation.
Scaling: 16384 100 % M
max
(C057)
nHeatsinktemperature_a
INT
Heatsink temperature
Identifier
Data type
Value/meaning