8 Diagnostics & error management
8.7 Error messages of the operating system
164
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
CE4: CAN bus off [xx.0131.00000]
CA06: CAN CRC error [xx.0131.00006]
CA07: CAN bus warning [xx.0131.00007]
CA08: CAN bus stopped [xx.0131.00008]
CA0b: CAN bus live time [xx.0131.00011]
Response (Lenze setting printed in bold) Setting: C592/2 ( Adjustable response)
None Fault Trouble WarningLocked
Cause Remedy
CAN on board: "Bus off" status
Received too many faulty telegrams.
Damaged cable (e.g. loose contact).
Two nodes have the same ID.
Check wiring and bus terminating resistor.
Set identical baud rate for each bus node.
Assign diiferent IDs to nodes.
Eliminate electrical interference (e.g. EMC).
Response (Lenze setting printed in bold) Setting: C592/1 ( Adjustable response)
None Fault Trouble WarningLocked
Cause Remedy
CAN on board: A faulty CAN telegram has been detected. Check wiring and bus terminating resistor.
Eliminate electrical interference (e.g. EMC).
Response (Lenze setting printed in bold) Setting: C592/3 ( Adjustable response)
None Fault Trouble WarningLocked
Cause Remedy
CAN on board: Incorrect transmission or reception of
more than 96 CAN telegrams.
The current number of incorrectly transmitted CAN
telegrams is displayed in C372/1
.
The current number of incorrectly received CAN tele-
grams is displayed in C372/2
.
The current CAN error status is displayed in C345
.
Check wiring and bus terminating resistor.
Set identical baud rate for each bus node.
Assign diiferent IDs to nodes.
Eliminate electrical interference (e.g. EMC).
Response (Lenze setting printed in bold) Setting: C592/4 ( Adjustable response)
None Fault Trouble WarningLocked
Cause Remedy
CAN on board: The device has received the "Stop Remote
Node" NMT telegram.
Check CAN master (NMT master).
Response (Lenze setting printed in bold) Setting: C592/5 ( Adjustable response)
None Fault Trouble WarningLocked
Cause Remedy
CAN on board: Cyclic node monitoring
Being a Heartbeat consumer, the device has not recei-
ved a Heartbeat telegram from Heartbeat producer 1
... 7 within the defined time.
The current states of the Heartbeat producers are dis-
played in C347/1...7
.
Reactivate Heartbeat producers by mains switching,
restarting the controller, or a CAN Reset Node.
Reparameterise CAN Heartbeat producer time or
switch off consumer monitoring and reset error sta-
tus if latched.
System bus "CAN on board": Heartbeat protocol