Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05 165
8 Diagnostics & error management
8.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
CA0F: CAN control word [xx.0131.00015]
CE1: CAN RPDO1 [xx.0135.00001]
CE2: CAN RPDO2 [xx.0135.00002]
PS01: No memory module [xx.0144.00001]
PS02: Par. set invalid [xx.0144.00002]
Response (Lenze setting printed in bold) Setting: C594/2 ( Adjustable response)
None Fault Trouble WarningLocked
Cause Remedy
Bit 14 ("SetFail") in the wCANControl control word of the
system block LS_DriveInterface
has been set.
Trace back signal source on the CAN bus that sets bit 14
("SetFail").
Response (Lenze setting printed in bold) Setting: C593/1 ( Adjustable response)
None Fault Trouble WarningLocked
Cause Remedy
CAN on board: Time monitoring for RPDO1 has tripped.
RPDO1 has not been received within the monitoring
time set in C357/1
or was faulty.
Set the correct telegram length at the CAN master
(transmitter).
Eliminate electrical interference (e.g. EMC).
Adjust monitoring time in C357/1
or switch off time
monitoring.
Response (Lenze setting printed in bold) Setting: C593/2 ( Adjustable response)
None Fault Trouble WarningLocked
Cause Remedy
CAN on board: Time monitoring for RPDO2 has tripped.
RPDO2 has not been received within the monitoring
time set in C357/2
or was faulty.
Set the correct telegram length at the CAN master
(transmitter).
Eliminate electrical interference (e.g. EMC).
Adjust monitoring time in C357/2
or switch off time
monitoring.
Response (Lenze setting printed in bold)
None Fault Trouble WarningLocked
Cause Remedy
Memory module is either not available or not snapped
into place correctly.
If a memory module has been provided: Plug the me-
mory module into the slot of the standard device in-
tended for this purpose.
If a memory module has been provided: Check if the
memory module has been plugged-in correctly.
Response (Lenze setting printed in bold)
None Fault Trouble WarningLocked
Cause Remedy
The parameter set saved to the memory module is inva-
lid because it has not been saved completely.
This can be due to voltage failure or caused by remo-
ving the memory module while saving the parameter
set.
Ensure voltage supply during the storage process and
that the module remains plugged into the slot.