Commissioning
Settings in the Lenze »Engineer«
32
Lenze · Decentralised frequency inverter 8400 motec (CANopen option) · EDS84DMOTCAN EN 4.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.4 Settings in the Lenze »Engineer«
The following settings can be made in the »Engineer« under the Settings tab:
CAN node address (C00350
)
The node address can only be parameterised if the node address "0" is set via the DIP
switches.
A change of the node address will only become effective after a CAN reset node.
CAN node is slave or master (C00352
)
Deceleration during status change from "Boot-up" to "Operational" (C00356/1
)
Time to the first transmission of CANx_OUT in the "Operational" state (C00356/4
)
Save changed settings with the device command C00002/11 (save all parameter sets).