Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 4.0 - 09/2013 58
Error messages
Possible causes and remedies
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Module parameter access failure [0x01bc6102]
Slave 1 data exchange timeout [0x01bc813a]
Slave 1 CTT2 extended cyclic timeout [0x01bc813b]
Slave 2 data exchange timeout [0x01bc813c]
Response (Lenze setting printed in bold) Setting: C01501/1 / C01503 ( adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
AS-i voltage supply interrupted.
Connection between the Communication Unit and
the Drive Unit defective.
Check wiring and terminals.
Switch the voltage supply of the AS-i network off and
on again.
If this error continues to occur, please contact the
Lenze service. (it might be necessary to replace the
Communication Unit.)
Response (Lenze setting printed in bold) Setting: C13207/1 / C13208/1 ( adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
AS-i communication / voltage supply interrupted.
The monitoring time is too low.
Check wiring and terminals.
Switch the voltage supply of the AS-i network off and
on again.
Check and raise the monitoring time.
Check and adjust the AS-i settings of the master.
Check and adjust the AS-i profile settings of the
master and the slaves.
Response (Lenze setting printed in bold) Setting: C13207/2 / C13208/2 ( adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
AS-i communication / voltage supply interrupted.
The monitoring time is too low.
Check wiring and terminals.
Switch the voltage supply of the AS-i network off and
on again.
Check and raise the monitoring time.
Check and adjust the CTT2 settings of the master.
Check and adjust the AS-i profile settings of the
master and the slaves.
Response (Lenze setting printed in bold) Setting: C13207/3 / C13208/3 ( adjustable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
AS-i communication / voltage supply interrupted.
The monitoring time is too low.
Check wiring and terminals.
Switch the voltage supply of the AS-i network off and
on again.
Check and raise the monitoring time.
Check and adjust the AS-i settings of the master.
Check and adjust the AS-i profile settings of the
master and the slaves.