Firmware 11.00 - DMS 8.0 EN - 10/2011 L 365
8400 StateLine C | Reference manual
Basic drive functions (MCK)
Holding brake control
Short overview of parameters for holding brake control:
Parameter Info Lenze setting
Value Unit
C02580 Holding brake: Operating mode 0: Brake control off
C02581/1
Holding brake: Switching threshold 5.00 %
C02581/2
Holding brake: Hyst. release 1.00 %
C02581/3
Holding brake: Hyst. close 1.00 %
C02581/4
Holding brake: FF control starting value 1 0 %
C02581/5
Holding brake: FF control starting value 2 0 %
C02582
Holding brake: Setting 0
C02589/1
Holding brake: Closing time 100 ms
C02589/2
Holding brake: Release time 100 ms
C02589/3
Holding brake: Waiting time status 100 ms
C02589/4
Holding brake: Ramp FF control 0 ms
C02593/1
Holding brake: Actual value monitoring 0.000 ms
C02593/2
Holding brake: Application delay 0.000 ms
C02610/1
MCK: Holding brake ramp time synchr. 2.000 s
C02607 Holding brake: Status -
C00830/68 MCK: nMBrakeAddValue_a - %
C00833/80 MCK: bMBrakeRelease -
C00833/81 MCK: bMBrakeStartValue2 -
C00833/82 MCK: bMBrakeApplied -
Highlighted in grey = display parameter