Firmware 11.00 - DMS 8.0 EN - 10/2011 L 413
8400 StateLine C | Reference manual
Diagnostics & error management
Error messages of the operating system
oS1: Maximum speed limit reached [xx.0123.00032]
oS2: Max. motor speed [xx.0123.00033]
Id1: Motor data identification error [xx.0123.00057]
Id3: CINH motor data identification [xx.0123.00058]
Id4: Resistor identification error [xx.0123.00059]
Response (Lenze setting printed in bold) Setting: C00579 (; Adjustable response)
: 0: No Reaction ; 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked ; 5: Warning 6: Information
Cause Remedy
The device has recognised that the maximum speed has
been reached.
Limit setpoint selection to maximum values.
Adjust set speed limitation (C00909
) and frequency
limitation (C00910
) if necessary.
Response (Lenze setting printed in bold)
0: No Reaction : 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause Remedy
The device has recognised that the maximally
permissible motor speed has been reached.
Limit setpoint selection to the maximally permissible
motor speed.
If required, adapt set maximum motor speed
(C00965
).
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop : 4: WarningLocked 5: Warning 6: Information
Cause Remedy
During the identification of the motor parameters, an
error has occurred.
Possible causes:
Interrupted motor cable.
Switched-off power section during the identification.
Implausible start parameter settings.
Check the motor connections and the corresponding
plug connector on the device and, if necessary, the
motor terminal box.
Correct start parameters for the motor parameter
identification (motor nameplate data).
Stable power supply of the device.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop : 4: WarningLocked 5: Warning 6: Information
Cause Remedy
The device has detected controller inhibit during the
motor data identification.
This cancels the identification process. The Lenze
setting of the motor data is used.
Do not set controller inhibit during the motor data
identification.
Do not execute any device function which may
activate controller inhibit.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked : 5: Warning 6: Information
Cause Remedy
The device has recognised that an error has occurred in
the calculation of the motor cable resistance.
The parameters for cable cross-section and cable
length are implausible.
Enter sensible values for cable cross-section and motor
cable length.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com