Firmware 11.00 - DMS 8.0 EN - 10/2011 L 419
8400 StateLine C | Reference manual
Diagnostics & error management
Error messages of the operating system
CE2: CAN RPDO2 [xx.0135.00002]
CE3: CAN RPDO3 [xx.0135.00003]
CP04: CAN RPDO4 [xx.0135.00004]
Cl01: Module missing/incompatible [xx.0140.00013]
PS01: No memory module [xx.0144.00001]
Response (Lenze setting printed in bold) Setting: C00593/2 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
CAN on board: Time monitoring for RPDO2 has tripped.
RPDO2 has not been received within the monitoring
time set in C00357/2
or was faulty.
Set the correct telegram length at the CAN master
(transmitter).
Eliminate electrical interference (e.g. EMC).
Adjust monitoring time in C00357/2
or switch off
time monitoring.
Response (Lenze setting printed in bold) Setting: C00593/3 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
CAN on board: Time monitoring for RPDO3 has tripped.
RPDO3 has not been received within the monitoring
time set in C00357/3
or was faulty.
Set the correct telegram length at the CAN master
(transmitter).
Eliminate electrical interference (e.g. EMC).
Adjust monitoring time in C00357/3
or switch off
time monitoring.
Response (Lenze setting printed in bold) Setting: C00593/4 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
CAN on board: Time monitoring for RPDO4 has tripped.
RPDO4 has not been received within the monitoring
time set in C00357/4
or was faulty.
Set the correct telegram length at the CAN master
(transmitter).
Eliminate electrical interference (e.g. EMC).
Adjust monitoring time in C00357/4
or switch off
time monitoring.
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
The optional communication module has been removed
or there is a connection problem or incompatibility with
the standard device.
Check connection between the communication
module and standard device.
Check if the module is plugged in correctly.
In case of an incompatibility, either the module or the
software of the standard device is out of date. In this
case, please contact Lenze.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked : 5: Warning 6: Information
Cause Remedy
Memory module is either not available or not snapped
into place correctly.
If a memory module has been provided: Plug the
memory module into the slot of the standard device
intended for this purpose.
If a memory module has been provided: Check if the
memory module has been plugged-in correctly.