Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011 L 419
8400 StateLine C | Reference manual
Diagnostics & error management
Error messages of the operating system
CE2: CAN RPDO2 [xx.0135.00002]
CE3: CAN RPDO3 [xx.0135.00003]
CP04: CAN RPDO4 [xx.0135.00004]
Cl01: Module missing/incompatible [xx.0140.00013]
PS01: No memory module [xx.0144.00001]
Response (Lenze setting printed in bold) Setting: C00593/2 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
CAN on board: Time monitoring for RPDO2 has tripped.
• RPDO2 has not been received within the monitoring
time set in C00357/2
or was faulty.
• Set the correct telegram length at the CAN master
(transmitter).
• Eliminate electrical interference (e.g. EMC).
• Adjust monitoring time in C00357/2
or switch off
time monitoring.
Response (Lenze setting printed in bold) Setting: C00593/3 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
CAN on board: Time monitoring for RPDO3 has tripped.
• RPDO3 has not been received within the monitoring
time set in C00357/3
or was faulty.
• Set the correct telegram length at the CAN master
(transmitter).
• Eliminate electrical interference (e.g. EMC).
• Adjust monitoring time in C00357/3
or switch off
time monitoring.
Response (Lenze setting printed in bold) Setting: C00593/4 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
CAN on board: Time monitoring for RPDO4 has tripped.
• RPDO4 has not been received within the monitoring
time set in C00357/4
or was faulty.
• Set the correct telegram length at the CAN master
(transmitter).
• Eliminate electrical interference (e.g. EMC).
• Adjust monitoring time in C00357/4
or switch off
time monitoring.
Response (Lenze setting printed in bold) Setting: C01501/2 (; Adjustable response)
: 0: No Reaction ; 1: Fault ; 2: Trouble ; 3: TroubleQuickStop ; 4: WarningLocked ; 5: Warning ; 6: Information
Cause Remedy
The optional communication module has been removed
or there is a connection problem or incompatibility with
the standard device.
• Check connection between the communication
module and standard device.
• Check if the module is plugged in correctly.
• In case of an incompatibility, either the module or the
software of the standard device is out of date. In this
case, please contact Lenze.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked : 5: Warning 6: Information
Cause Remedy
Memory module is either not available or not snapped
into place correctly.
• If a memory module has been provided: Plug the
memory module into the slot of the standard device
intended for this purpose.
• If a memory module has been provided: Check if the
memory module has been plugged-in correctly.