12.3.9 High resolution data
Under
Codes
C380
to C382 you
tan
enter very
precise
setpoint
and
act. value with a resolution of 14 bit plus sign.
Setpoint
1:
Setpoint
scaled to the maximum frequency. The value of
214
corresponds to 100% of the maximum field frequency. The
inforrnation is identical with that
under
C046, with the
differente
that you
tan
read the controller value directly thus excluding
conversion errors.
Total
setpoint:
Total of main
setpoint
1 and
setpoint
2,
each
behind the ramp
generator, scaled to the maximum field frequency. The total
setpoint
corresponds to the
setpoint
of the PI controller in
closed-
loop control. The value of
214
corresponds to 100% of the
maximum field frequency.
Act. value of PI controller
Act. value for the Pl controller, scaled to the maximum field
frequency. The value of
214
corresponds to 100% of the maximum
field frequency. The information is identical with that
under
CO51,
with the
differente
that you
tan
read the controller value directly
thus excluding conversion errors.
Parameter Meanlng
-
16384 to +16384
Setpoint 1
-76384 to
+16384
Total
setpoint
-16384 to
+16384
Act. value of PI controller
Acceptance
only display
only display
lmue