6.1
.l
Selection
of the brake resistor
l The following
combinations
ensure
-
a maximum braking time of 15 seconds
-
a maximum relative duty time of 10%.
l The set continuous power of the
controller
is the reference for the
combination.
Operation at rated power (factory setting)
8602 8603 8604 8605
370 240 180 180
0.15 0.2 0.3 0.3
ERBM370R150W
ERBM370R150W
ERBM240R200W
ERBDl80R300W
ERBDl80R300W
8607 8608 8609 8610
100 68 47 33
0.6 0.8 1.2 2.0
ERBDlOOR600W
ERBDlOOR600W
ERBD068R800W
ERBD047ROl
K2
ERBD033R02KO
8612 8613 8614 8615
22 15 15 15
-
3.0 4.0 4.0 4.0
ERBD033R02KO
ERBD022R03KO
ERBD015R04KO
ERBD015R04KO
ERBDOl5R04KO
Operation at increased power
8602 8603 8604 8605
240 180 180 180
0.2 0.3 0.3 0.3
ERBM37OR150W
ERBM240R200W
ERBD180R300W
ERBD180R300W
ERBD180R300W
1
8607 8608 8609 8610
100 47 33 33
0.6 1.2 2.0 2.0
ERBDl
OOR600W
ERBDlOOR600W
ERBDO47ROl
K2
ERBD033R02KO
ERBD033R02KO
Controller
F
8611 8612 8613
8614 8615
t e
ResistancelR
33 15 15 15 15
Power/kW
2.0 4.0 4.0 4.0 4.0
Order no.
ERBD033R02KO
ERBD015RO4KO
ERBD015RO4KO
ERBD015R04KO
ERBD015R04KO
-
Operation at maximum power
8602 8603 8604 8605
180 180 180
-
0.3 0.3 0.3
-
ERBM240R200W
ERBD180R300W
ERBD180R300W
ERBD180R300W
-
Controller
8606 8607 8608 8609 8610
type
Resistance/Q
100
-
33 33 33
Power/kW
0.6
-
2.0 2.0 2.0
Order no.
ERBDl
OOR600W
-
ERBD033R02KO
ERBD033ROZ’KO
ERBD033R02KO
t e
E
Controller
Resistanceli2
Power/kW
8611
-
-
8612
4.0 15
8613
4.0 15
8614
4.0 15
-
8615
-
Order no.
-
ERBDOI
5R04KO
ERBDO15R04KO
ERBDOI
5R04KO
-
A
higher
brake power
tan
be obtained by using other resistors or by connecting several
resistors in parallel or in series. However, the
minimum
resistance given on page 38 must
be maintained!
39