Closed-loop speed control
For a number of applications, the accuracy which
tan
be obtained
with open-loop
Speed
control is often not
sufficient.
To avoid a
Speed
reduction
which occurs when an asynchronous motor is
loaded, you
tan
select a configuration with a Pl
controller.
The
appropriate configuration depends on the way of
setpoint
input and
the
actual
value input you want to use.
Closed-loop
Speed
control:
Code
f-
Parameter Meaning
Acceptance
Setpoint
1
Setpoint
2
Actual
value
CO05
-1
l-
Terminals 7/8 (bipolar) or Terminals
1/2
Terminals 3/4 [SH
+
PRG]
LECOM (bipolar) or keypad (bipolar) analog act. value
(bipolar)
-13-
Terminals 7/8 (bipolar) or Terminals
1/2
Input X5
LECOM (bipolar) or keypad (bipolar) Digital frequency (2-
1
(bipolar) track)
-14-
l
Input X8
Terminals
1/2
Input X5
Digital frequency (2-track)
(bipolar) Digital frequency
(2-
track)
-15-’ Input X5 Terminals
1/2
Input X8
Digital frequency (2-track) (bipolar)
Pulse encoder (2-
track)
* According to the configuration selected, setpoint 1 or the act. value tan be
output via the digital frequency output XQ.
4.1
Analog act. value
If you use a DC tachogenerator, you should know the maximum
tacho voltage to be expected. You
tan
calculate this tacho voltage
from the ratings of the tacho and the maximum drive
Speed.
Connect the tacho to input
Xl/terminals
3, 4, and select the
Position
of the
switch
SI, which is required for the maximum tacho
voltage (see page 31).
4.2
Digital act. value
If you use an incremental encoder for act. value, first select the
input for this encoder
under
code
CO25. To enter the encoder
constant,
two
Steps
are necessaty in general:
l
Z;elect
the
closest
value
under
C026.
l Compensate the
differente
under
C027.
Encoder
constant
=
Pulses per revolution of the
encodei
Pole pair number of the motor
Adjustment (C027) =
Constant (C026)
Encoder
constant
Name
Parameter
(Factory setting
is
printed in bold)
Acceptance
Preselection:
-l-
Analog input Xl/terminals
112
SH + PRG
Encoder -2- Analog input Xl/terminals 3/4
-4
Analog input
Xl/terminal
8
-lO-
Digital frequency/incrementaI encoder
input X5
-ll-
Digital frequencyfincremental encoder