5.2.5 Additional acceleration and deceleration times
For the ramp generator of the main
setpoint
(setpoint
l/JOG
frequency) you
tan
cal1
additonal acceleration and deceleration
times from the memory, e.g. to
Change
the acceleration
Speed
of
the drive as from a certain
Speed.
Programming of additional acceleration and deceleration
times
The ramp times are set in two
Steps,
under
ClOO,
one pair of
acceleration and deceleration times is selected.
l
Select an additional
acceleration/deceleration
time
under
Cl 00
l
Set the desired acceleration time
under
Cl01
and the desired
deceleration time
under
Cl 03.
If
you need several additional ramp times, repeat the two
Steps
correspondingly.
To calculate the values to be entered, please observe the information
on page 74.
A maximum of 15 additional acceleration and deceleration times
tan
be programmed.
Code (Name 1
Parameter (Factory
setting is printed in
hold)
Acceptanct
Cl 00 I Preselection:
l-l-
Pair of ramp times 1
kH
+ PRG
Additional -2-
Pair of
ramp
times 2
acceleration
/
. . . .
deceleration
-15
Pair of ramp times 15
time
Cl01
Acceleration
2.5 s 0.00 s
[IO
ms)
1
.OO
s ON-LINE
time for Cl 00
1.0 s
(100 ms) 10.0s
10s
(1
SI
100s
100s
IlO)
990 s
Cl 03 Deceleration 2.5 s
time for
Cl00
0.00 s
(10
ms)
1
.OO
s ON-LINE
1.0 s
(100 ms)
10.0s
10s
(1
SI
100s
100s
(10)
990 s
Assignment of the digital inputs
The number of required inputs for the function “Enable additional
acceleration/deceleration times” depends on the amount of the
required additional ramp times.
I
-
Number of required acceleration and deceleration
times
Number of required Inputs
1
2...3
4...7
8...15
1
at least
1
at least
2
at least 3
4
A maximum of four inptus
tan
be assigned to this function. For the
assignment of the inputs see the
notes
on page 81.
-
86