7
2.2.2. Rated data of axis modules
Axis module type 9222_E 9223_E 9224_E 9225_E
Order no. 33.9222_E 33.9223_E 33.9224_E 33.9225_E
Output current
(f
ch
= 8 kHz)
[A
eff
] 4.5 5.5 13.5 18
Output current
(f
ch
= 16 kHz)
[A
eff
] 2.3 2.9 6.9 9.5
Peak current
(for t = 5 s at f
ch
= 8 kHz;
for t = 2.5 s at f
ch
= 16 kHz)
[A
eff
] 8 10 24 33
Permanent power
(V
A
= 3 x 480 V and f
ch
= 8 kHz)
[kVA] 3.7 4.5 11.2 14.9
Permanent power
(V
A
= 3 x 480 V and f
ch
= 16 kHz)
[kVA] 1.9 2.4 5.7 7.9
Peak power
(V
A
= 3 x 480 V)
[kVA] 6.6 8.3 19.9 27.4
Output voltage V
A
[V] 3 x 0...V
mains
Field frequency
[Hz] 0...
±
300
Speed
[min
-1
] 0...
±
8000
Power loss at permanent power
[W] 200 250 340 510
Power loss at controller inhibit
[W]454545125
Weight
[kg] 9.2 9.5 9.5 20.5
Type 9226_E 9227_E 9228_E
Order no. 33.9226_E 33.9227_E 33.9228_E
Output current
(f
ch
= 8 kHz)
[A
eff
]25 32 46
Output current
(f
ch
= 16 kHz)
[A
eff
] 13 16.5 23.5
Peak current
(for t = 5s at f
ch
= 8kHz;
for t = 2.5 s at f
ch
= 16kHz)
[A
eff
]45 57 82
Permanent power
(V
A
= 3 x 480 V and f
ch
= 8 kHz)
[kVA] 20.2 26.6 38.2
Permanent power
(V
A
= 3 x 480 V and f
ch
= 16 kHz)
[kVA] 10.8 13.7 19.5
Peak power
(V
A
= 3 x 480 V)
[kVA] 37.4 47.3 68.1
Output voltage V
A
[V] 3 x 0...V
mains
Field frequency
[Hz] 0...
±
300
Speed
[min
-1
] 0...
±
8000
Power loss at permanent power
[W] 640 800 1000
Power loss at controller inhibit
[W] 125 125 125
Weight
[kg] 21 22 22