Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Changing and saving parameters
7
7.2
7.2.4
7.2−5
EDSVF9383V EN 7.1−04/2012
ActionKey
sequence
Step
( )
(
Quick change of digit
7.
Accept the changed parameter
Display of SHPRG or SHPRG ' ( Confirm change to accept the parameter
Display "OK"
Display ' The parameter has been accepted
immediately
8. Enable the controller, if
required
1)
The drive runs again
9.
Change to the code level
A Display of the operating level
B Display of the code with changed
parameter
10. Change further parameters Restart the "loop" with step 1. or 3.
11.
Save changed parameters
A ) * Select the code C0003 "PAR SAVE" in the
menu "Load/Store"
B Change to the parameter level
Display "0" and "READY"
Select the parameter set
in which the parameters
are to be saved
permanently
C
Save as parameter set 1:
ð Set "1" "Save PS1"
Save as parameter set 2:
ð Set "2" "Save PS2"
Save as parameter set 3:
ð Set "3" "Save PS3"
Save as parameter set 4:
ð Set "4" "Save PS4"
D ( When "OK" is displayed, the settings are
permanently saved in the selected
parameter set.
12.
Change to the code level
A Display of the operating level
B Display of C0003 "PAR SAVE"
13. Set parameters for another
parameter set
Restart the "loop" with step 1. or 3.
1)
The function of the + key can be programmed:
C0469 = 1: Controller inhibit
C0469 = 2: Quick stop (Lenze setting)