Configuration
Code table
8
8.5
8.5−24
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0360 0 65535 Telegram counter
l Read only
l For count values > 65535 the
counter starts at 0
1 Message OUT All telegrams sent
2 Message IN All telegrams received
3 Message OUT1 Telegrams sent on CAN−OUT1
4 Message OUT2 Telegrams sent on CAN−OUT2
5 Message OUT3 Telegrams sent on CAN−OUT3
6 Message
POUT1
Telegrams sent on parameter
channel1
7 Message
POUT2
Telegrams sent on parameter
channel2
8 Message IN1 Telegrams received from CAN−IN1
9 Message IN2 Telegrams received from CAN−IN2
10 Message IN3 Telegrams received from CAN−IN3
11 Message PIN1 Telegrams received from
parameter channel1
12 Message PIN2 Telegrams received from
parameter channel2
C0361 0 {1 %} 100 System bus load
l Read only
l For a perfect operation, the
entire bus load (all nodes
connected) should be less than
80 %
1 Load OUT All telegrams sent
2 Load IN All telegrams received
3 Load OUT1 Telegrams sent on CAN−OUT1
4 Load OUT2 Telegrams sent on CAN−OUT2
5 Load OUT3 Telegrams sent on CAN−OUT3
6 Load POUT1 Telegrams sent on parameter
channel1
7 Load POUT2 Telegrams sent on parameter
channel2
8 Load IN1 Telegrams received from CAN−IN1
9 Load IN2 Telegrams received from CAN−IN2
10 Load IN3 Telegrams received from CAN−IN3
11 Load PIN1 Telegrams received from
parameter channel1
12 Load PIN2 Telegrams received from
parameter channel2
C0364
CFG: CAN activ 1000 FIXED0 Selection list 2 Configuration − digital input signal
l Switches the system bus via
the external signal from
"Pre−Operational" to
"Operational"
C0365 DIS:CAN activ
0 Pre−Operational
System bus state
l Display only
1 Operational
C0366 Sync Response 1
0 No response
Response to sync telegram of the
master
1 Response
C0367 Sync Rx ID 128 1 {1} 256 Receipt identifier (Rx)
l Sync Identifier for grouping for
data transfer to CAN−IN1