Configuration
Code table
8
8.5
8.5−39
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0671 RFG1 Tir 0.00 0.00 {0.01 s} 999.90
Acceleration time T
ir
and
deceleration time T
if
, function
block RFG1
l Acceleration and deceleration
ramp
See System
Manual
(extension)
C0672 RFG1 Tif 0.00 0.00 {0.01 s} 999.90
C0673
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block RFG1
l Selection of a final value at
RFG1−OUT
C0674
CFG: SET 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block RFG1
l Selection of a starting value at
RFG1−OUT
C0675
CFG: LOAD 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block RFG1
l HIGH: RFG1−OUT is set to the
value at RFG1−Set
l LOW: The signal at RFG1−OUT
travels along the ramps
towards the input value at
RFG1−IN
C0676 −199.99 {0.01 %} 199.99 Function block RFG1
l Display of the signals linked in
C0673 and C0674
1 DIS: RFG1 RFG1−IN
2 DIS: RFG1 RFG1−SET
C0677 DIS: LOAD 0 1 Function block RFG1
l Display of the signal linked in
C0675
C0680 Function 1
1 IN1 = IN 2
Function selection, function block
CMP1
l Compare input signals at
CMP1−IN1 and CMP1−IN2
See System
Manual
(extension)
2 IN1 > IN2
3 IN1 < IN2
4 |IN1IN2|
5 |IN1IN2|
6 |IN1IN2|
C0681 Hysteresis 1.00 0.00 {0.01 %} 100.00 Hysteresis, function block CMP1
l Hysteresis for input signals
which are not stable and hence
the output oscillates
C0682 Window 1.00 0.00 {0.01 %} 100.00 Window, function block CMP1
l Set the range in which the
signal comparison is to be
apply
C0683
Selection list 1 Configuration of analog input
signal, function block CMP1
1 CFG: IN 5001 MCTRL−NACT CMP1−IN1
2 CFG: IN 19500 FCODE−17 CMP1−IN2
C0684 −199.99 {0.01 %} 199.99 Function block CMP1
l Display of the signals linked in
C0683
1 DIS: IN CMP1−IN1
2 DIS: IN CMP1−IN2