Configuration
Code table
8
8.5
8.5−59
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0961 y0 0.00 0.00 {0.01 %} 199.99 Configuration of base point y0,
function block CURVE1
l Ordinate of the value pair
(x = 0 % / y0)
See System
Manual
(extension)
C0962 y1 50.00 0.00 {0.01 %} 199.99 Configuration of base point y1,
function block CURVE1
l Ordinate of the value pair (x1 /
y1)
C0963 y2 75.00 0.00 {0.01 %} 199.99 Configuration of base point y2,
function block CURVE1
l Ordinate of the value pair (x2 /
y2)
C0964 y100 100.0 0.00 {0.01 %} 199.99 Configuration of base point y100,
function block CURVE1
l Ordinate of the value pair
(x 100 % / y100)
C0965 x1 50.00 0.01 {0.01 %} 99.99 Configuration of base point x1,
function block CURVE1
l Abscissa of the pair (x1 / y1)
C0966 x2 75.00 0.01 {0.01 %} 99.99 Configuration of base point x2,
function block CURVE1
l Abscissa of the pair (x2 / y2)
C0967
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block CURVE1
See System
Manual
(extension)
C0968 DIS: IN −199.99 {0.01 %} 199.99 Function block CURVE1
l Display of the signal linked in
C0967