Electrical installation
Wiring of the feedback system
Important notes
5
210
EDKVS9332X DE/EN/FR 8.0
5.10 Wiring of the feedback system
5.10.1 Important notes
The feedback signal can either be supplied via input X7 or via input X8.
ƒ At X7 a resolver can be connected.
ƒ At X8 an encoder can be connected.
Incremental encoder TTL
SinCos encoder
SinCos encoder with serial communication (single−turn or multi−turn)
The resolver or encoder signal for slave drives can be output at the digital frequency output
X10.
Note!
ƒ We recommend to use Lenze system cables for wiring.
ƒ For self−made cables only use cables with shielded cores twisted in pairs.
Installation material required from the scope of supply:
Description Use Quantity
Protective cover Protection for unused Sub−D connections 4