Configuration
Code table
8
8.5
8.5−65
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1090 Output signal −2147483648 {1} 2147483647 Function block FEVAN1
l Display of the converted
signal
See System
Manual
(extension)
C1091 Code 141 2 {1} 2000 Code, function block FEVAN1
l Selection of the target code
in which the calculated value
is to be written
C1092 Subcode 0 0 {1} 255 Subcode, function block FEVAN1
l Selection of the target
subcode in which the
calculated value is to be
written
C1093 Numerator 1.0000 0.0001 {0.0001} 100000.0000 Numerator, function block
FEVAN1
l Scaling of the input signal
See System
Manual
(extension)
C1094 Denominator 0.0001 0.0001 {0.0001} 100000.0000 Denominator, function block
FEVAN1
l Scaling of the input signal
C1095 Offset 0 0 {1} 1000000000 Offset, function block FEVAN1
l An offset can be added to the
converted signal
C1096
CFG: IN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block FEVAN1
See System
Manual
(extension)
C1097
CFG: LOAD 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block FEVAN1
l A LOW−HIGH edge transmits
the converted signal to the
target code
C1098 DIS: IN −32768 {1} 32767 Function block FEVAN1
l Display of the signal linked in
C1096
See System
Manual
(extension)
C1099 DIS: LOAD Function block FEVAN1
l Display of the signal linked in
C1097
C1100 Function 1
Function selection, function
block FCNT1
See System
Manual
(extension)
1 Return At |counter
content| ³ |FCNT1−CMP−Val|
FCNT1−EQUAL is set to HIGH for
1 ms
2 Hold if >= At |counter
content| ³ |FCNT1−CMP−Val| the
counter stops
3 Hold if = At |counter
content| = |FCNT1−CMP−Val| the
counter stops
C1101
Selection list 1 Configuration of analog input
signals, function block FCNT1
See System
Manual
(extension)
1 CFG: LD−VAL 1000 FIXED0% l Starting value
2 CFG: CMP−VAL 1000 FIXED0% l Comparison value
C1102
Selection list 2 Configuration of digital input
signals, function block FCNT1
See System
Manual
(extension)
1 CFG: CLKUP 1000 FIXED0 LOW−HIGH edge counts
upwards by one
2 CFG: CLKDWN 1000 FIXED0 LOW−HIGH edge counts
downwards by one
3 CFG: LOAD 1000 FIXED0 l HIGH = accepts starting value
l Input signal has highest
priority