Configuration
Code table
8
8.5
8.5−67
EDSVF9383V EN 4.0−03/2006
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1300
N−motor/
Dmax
300 −32767 {1 rpm} 32767 Motor speed at D
max
, function
block DCALC1
l Nominal speed of the
winding drive
8.2−1
C1301
N−line max 3000 1 {1 rpm} 32767 Maximum line speed, function
block DCALC1
l Nominal speed of the line
drive
C1302 calc cycle 0.1 0.1 {0.1 rev} 100.0 Calculation cycle, function block
DCALC1
8.2−1
C1303 time const 0.10 0.01 {0.01 s} 50.00 Filter time constant, function
block DCALC1
C1304
Dmax 500 1 {1 mm} 10000 Maximum diameter, function
block DCALC1
l Nominal winding diameter
8.2−1
C1305 lower D−limit 50 1 {1 mm} 10000 Lower diameter limit, function
block DCALC1
l Minimum winding diameter
C1306 upper D−limit 500 1 {1 mm} 10000 Upper diameter limit, function
block DCALC1
l Maximum winding diameter
C1307 hyst D−limit 1.00 0.00 {0.01 %} 100.0 Hysteresis − diameter limitation,
function block DCALC1
l Hysteresis for D
min
/D
max
output
C1308
arit function 1
0 DCALC1−OUT=D DCALC1−OUT =
diameter
Selection of the arithmetic
function, function block DCALC1
8.2−1
1 DCALC1−OUT=1/D DCALC1−OUT =
1/diameter
C1309
Dmin 50 1 {1 mm} 10000 Minimum diameter, function
block DCALC1
8.2−1
C1310 DCALC1−Titim
e
0.000 0.000 {0.001 s} 999.900 Acceleration and deceleration
time, function block DCALC1
C1311 window D−calc 1.00 0.00 {0.01 %} 100.00 Window − diameter calculation,
function block DCALC1
l Window setting for
permissible diameter
deviation
C1320
CFG: SET 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block DCALC1
l The signal is scaled to the
value in C1304
(100 % ¢ C1304)
8.2−1
C1321
Selection list 2 Configuration of digital input
signals, function block DCALC1
1 CFG: LOAD 1000 FIXED0 l HIGH: initial value at
DCALC1−SET is accepted
l DCALC1−LOAD has a higher
priority than DCALC1−HOLD
2 CFG: HOLD 1000 FIXED0 l HIGH = holds the diameter
value reached and resets the
integrators.