Function library
7-83
L
EDSVS9332P-D21 EN 3.0
Monitoring in stand-by operation
•
Monitoring of the travel range limit switch is active (fault P01, P02).
•
Monitoring of the position limit value is active (fault P04, P05).
•
Endless operation is possible with relative positioning (1210 = 1). The position values
(POS-SETPOS and POS-ACTPOS) are reset to 0 when reaching half the position limiting
value; the current following error remains the same (no jerking).
•
The following error monitoring of the positioning (P14, P15) is not active in stand-by operation.
Tip!
The stand-by operation is terminated when the program is reset (see program control) or manual
operation is activated (see manual operation).
•
Firmware version
≥
2.5:
– If the program is interrupted by CINH or QSP the stand-by operation is interrupted. After a
renewed program start the stand-by operation will be continued.
– New profile parameters can be accepted in the stand-by operation using PARAM-RD.
•
Firmware version < 2.5:
– If the program is interrupted by CINH (controller inhibit) or QSP (see program control) the
stand-by operation will be continued. The stand-by operation cannot be aborted. The
program must be restarted.
– The profile parameters and override inputs are not read in anew.