Function library
7-206
L
EDSVS9332P-D21 EN 3.0
FEVAN5-IN
C1538
C1536
C1533
C1534
CTRL
+
+
C1535
S&H
C1539/1
FEVAN5-LOAD
C1537/1
C1530
Code/Subcode
(Cxxxx/yy)
C1532
C1531
FEVAN5-BUSY
FEVAN5
³
1
C1539/2
FEVAN5-BUSY-IN
C1537/2
³
1
C1539/3
FEVAN5-FAIL-IN
C1537/3
FEVAN5-FAIL
Fig. 7-161 Freely assignable input variables (FEVAN5)
Signal
Source Note
Name Type DIS DIS format CFG List
FEVAN5-IN a C1538 dec C1536 1 Input value
FEVAN5-LOAD d C1539/1 bin C1537/1 2 A LOW-HIGH edge transmits the converted signal to the
target c ode.
FEVAN5-BUSY-IN d C1539/2 bin C1537/2 2 HIGH = transmitting
FEVAN5-FAIL-IN d C1539/3 bin C1537/3 2 HIGH = transmission failed
FEVAN5-BUSY d - - - - HIGH = transmitting
FEVAN5-FAIL d - - - - HIGH = transmission failed
A LOW-HIGH edge at FEFAN5-LOAD sets FEF AN5-FAIL
=LOW.
- - C1530 - - - Display of the converted signal
FEVAN6-IN
C1548
C1546
C1543
C1544
CTRL
+
+
C1545
S&H
C1549/1
FEVAN6-LOAD
C1547/1
C1540
Code/Subcode
(Cxxxx/yy)
C1542
C1541
FEVAN6-BUSY
FEVAN6
³
1
C1549/2
FEVAN6-BUSY-IN
C1547/2
³
1
C1549/3
FEVAN6-FAIL-IN
C1547/3
FEVAN6-FAIL
Fig. 7-162 Freely assignable input variables (FEVAN6)
Signal
Source Note
Name Type DIS DIS format CFG List
FEVAN6-IN a C1548 dec C1546 1 Input value
FEVAN6-LOAD d C1549/1 bin C1547/1 2 A LOW-HIGH edge transmits the converted signal to the
target c ode.
FEVAN6-BUSY-IN d C1549/2 bin C1547/2 2 HIGH = transmitting
FEVAN6-FAIL-IN d C1549/3 bin C1547/3 2 High = transmission fai led
FEVAN6-BUSY d - - - - HIGH = transmitting
FEVAN6-FAIL d - - - - HIGH = transmission failed
A LOW-HIGH edge at FEFAN6-LOAD sets FEF AN6-FAIL
=LOW.
- - C1540 - - - Display of the converted signal