Function library
7-280
L
EDSVS9332P-D21 EN 3.0
7.5.81.3 Evaluate positive or negative edge
t
t
TRANS1-IN
TRANS1-OUT
C0711
C0711
Fig. 7-229 Evaluation of positive and negative edges (TRANS1)
•
The output TRANSx-OUT is set to HIGH as soon as a HIGH-LOW edge or a LOW-HIGH edge
is sent to the input.
•
After the time set under C0711 or C0716 has elapsed, the output changes again to LOW
unless there is another HIGH-LOW edge or LOW-HIGH edge at the input.