Function library
7-282
L
EDSVS9332P-D21 EN 3.0
Function
A total of 34 table positions is available.
•
Enter fixed values under C1303.
– 30 table positions (VTACC-No1 ... VTACC-No30) are available.
– Subcodes (C1303/1 ... C1303/30) define the table position number.
•
Enter variable values in VTACC-INx.
– 4 table positions (VTACC-No31 ... VTACC-No34) are available.
– Signal input via function blocks.
– The values must be transmitted to the table positions before the corresponding program set
starts and accesses these values.
•
C1384 indicates the values (in % of amax) on the table positions.
– Select table position (C1384/1 ... C1384/34) with subcode.
•
C1385 displays the values (in inc) on the table positions.
– Select table position (C1385/1 ... C1385/34) with subcode.
•
The conversion from a [units/s
2
]toa[inc]isperformedaccordingtothe
formula:
a[inc]= a [units∕s
2
] ⋅
65536 [inc∕r] ⋅ gear nominator ⋅ 16384
Feed const. [units∕r] ⋅ gear denominator ⋅ 1000000 [1∕s
2
]
Tip!
Entries into the processing table are only required if FB inputs and outputs are used.