Configuration
7-326
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0032 FCODE GEARBOX 1 -32767 {1} 32767 FCODE (gearbox factor numerator)
Freely assignable code
C0033 GEARBOX DENOM 1 1 {1} 32767 Gearbox factor denominator
C0034 MST CURRENT 0 0
1
2
-10V...+10V
+4 mA ... +20 mA
-20mA...+20mA
Master voltage/master current
Selection for setpoint selection
C0037 SET-VALUE RPM 0 -16000 {1 rpm} 16000 Setpoint selection (rpm)
C0039 -199.99 {0.01 %} 199.99
NSET JOG setpoints
1 JOG SET-VALUE 100.00
Fixed speeds (JOG setpoints) can be selected
2 JOG SET-VALUE 75.00
or NSET using digi
al inpu
s
3 JOG SET-VALUE 50.00
4 JOG SET-VALUE 25.00
5 JOG SET-VALUE 0.00
... ... ...
14 JOG SET-VALUE 0.00
15 JOG SET-VALUE 0.00
C0040 CTRL ENABLE 1 0
1
“write”, controls the code
“read”, reads controller sta tus
Controller enable RFR
C0042 QSP
0
1
2
QSP inactive
QSP active
Quick stop
C0043 TRIP RESET 0 0
1
Trip reset
Active error
Trip reset
Resetofanactivetrip:
Set C0043 = 0
C0045 ACT JOG
0
0
1
2
...
15
Nset active
JOG 1
JOG 2
...
JOG 15
NSET
JOG selection
C0046 NSET-N
0
-199.99 {0.01 %} 199.99 NSET
Main setpoint
C0049 NSET-NADD
0
-199.99 {0.01 %} 199.99 NSET
Additional setpoint
C0050 MCTRL- NSET2
0
-100.00 {0.01 %} 100.00 MCTRL
n
set
at speed controller input
C0051 MCTRL-NACT
0
-30000 {1 rpm} 30000 Actual speed value
C0052 MCTRL-UMOT
0
0 {1 V} 800 Motor voltage
C0053 UG-VOLTAGE
0
0 {1 V} 900 DC-bus voltage
C0054 IMOT
0
0.0 {0.1 A} 300.0 Imot (Motor current)
C0056 MCTRL-MSET2
0
-100.00 {0.01 %} 100.00 MCTRL
Torque setpoint (speed controller output) with M
precontrol (MCTRL-M-ADD)
C0057 MAX TORQUE
0
0 {1 Nm} 400 Maximum torque (C0086/C0022)
Maximum possible torque of the drive
configuration
depending on C0022, C0086
C0058 ROTOR DIFF 0.0 -180.0 {0.1 °} 179.9 Rotor angle
Zero phase of the rotor for synchronous motors
(C0095)
C0059 MOT POLE NO.
0
1 {1} 50 Number of motor pole pairs
C0060 ROTOR POS
0
0 {1} 2047 Motor rotor position
1 rev. = 2048 inc
C0061 HEATSINK TEMP
0
0 {1 °C} 100 Heatsink temperature
C0063 MOT TEMP
0
0 {1 °C} 200 Motor temperature
C0064 UTILISATION
0
0 {1 %} 150 Device utilisation Ixt
Utilisation of the last 180 s
C0064 > 100 % releases Trip OC5
Trip reset is possible only if C0064 < 95 %