Configuration
7-327
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0067 ACT TRIP
0
All fault indications
Æ
Selection list 10 Error message TRIP
Momentary fault indication
C0070 VP SPEED CTRL
Æ
0.0 {0.5} 255.0 V
pn
speed controller
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
C0071 TN SPEED CTRL
Æ
1.0 {0.5 ms} 600.0 T
nn
Speed controller
>512 ms: Switched off
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
C0072 TD SPEED CTRL 0.0 0.0 {0.1 ms} 32.0 T
dn
speed controller
C0075 VP CURR CTRL 0.35 0.00 {0.01} 15.99 V
pi
current controller
C0076 TN CURR CTRL 1.8 0.5 {0.1 ms} 1999.0 T
ni
current controller
2000 ms: Switched off
C0077 VP FI ELD CTRL 0.25 0.00 {0.01} 15.99 V
pF
field controller
C0078 TN FI ELD CTRL 15.0 1.0 {0.5 ms} 7999.0 T
nF
field controller
8000 ms: Switched off
[C0081] MOT POWER
Æ
0.01 {0.01 kW} 500.00 Rated motor power ac c. to namepla te
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
Change of C0081 sets C0086 = 0
[C0084] MOT RS
Æ
0.00 {0.01 Ω} 100.00 Motor s tator resistance
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0085] MOT LS
Æ
0.00 {0.01} 200.00 Motor leakage inductance
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0086] MOT TYPE
Æ
see motor selection list Motor selection
Æ
depending on the controll e r used
•
Change of C0086 resets C0006, C0022,
C0070, C0071, C0081, C0084, C0085,
C0087, C0088, C0089, C0090, C0091 to the
assigned default setting
Controller Lenze setting Assigned motor type Lenze motor type
9321 110 MDSKS56-23-150 MDSKSXX056-23, f
N
: 150Hz
9322 111 MDSKS56-33-150 MDSKSXX056-33, f
N
: 150Hz
9323 112 MDSKS71-13-150 MDSKSXX071-13, f
N
: 150Hz
9324 116 MDSKS71-33-150 MDSKSXX071-33, f
N
: 150Hz
9325 15 MDFKA80-120 MDFKAXX080-22, f
N
: 120Hz
9326 19 MDFKA90-120 MDFKAXX090-22, f
N
: 120Hz
9327 23 MDFKA100-120 MDFKAXX100-22, f
N
: 120Hz
9328 27 MDFKA112-120 MDFKAXX112-22, f
N
: 120Hz
9329 225 30kW-ASM-50 –
9330 227 45kW-ASM-50 –
9331 228 55kW-ASM-50 –
9332 229 75kW-ASM-50 –
[C0087] MOT SPEED
Æ
300 {1 rpm} 16000 Rated motor speed
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0088] MOT CURRENT
Æ
0.5 {0.1 A} 500.0 Rated motor current
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0089] MOT FREQUENCY
Æ
10 {1 Hz} 1000 Rated motor frequency