Configuration
7-328
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
[C0090] MOT VOLTAGE
Æ
50 {1 V} 500 Rated motor voltage
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
[C0091] MOT COS PHI
Æ
0.50 {0.01} 1.00 Motor cos ϕ
Æ
depending on C0086
Change of C0086 resets value to the assigned
default setting
C0093 DRIVE IDENT
0
0
1
93xx
invalid
none
93xx
Controller identification
93xx: Lenze position controller
C0094 PASSWORD 0 0 {1} 9999 P assword
Parameter access protection for the keypad.
When the password is activated only the codes
of the user menu can be accessed. For further
possible selections see C0096
[C0095] ROTOR POS ADJ 0 0
1
inactive
active
Rotor position adjustment of a synchronous
motor
C0058 displays the zero angle of the rotor
C0095 = 1 starts position adjustment
[C0096]
0
1
2
No password protection
Read protection
Write protection
Extended password protection for bus systems
with activated password (C0094).
All codes in the user menu can be accessed.
1 AIF PROTECT. 0
3
Read/Write protection
AIF access protection
2 CAN PROTECT. 0 CAN access protection
C0099 S/W VERSION
0
x.xx Software version
C0101 0.000 {0.001 s} 999.900
NSET
1 ADD-TIR 0.000
Additional acceleration for the main setpoint
2 ADD-TIR 0.000
(referring to speed variation of 0 ... n
max.
)
... ... ...
15 ADD-TIR 0.000
C0103 0.000 {0.001 s} 999.900
NSET
1 ADD-TIF 0.000
Additional deceleration times for the main
2 ADD-TIF 0.000
se
poin
... ... ...
re
err
ng
o spee
var
a
on o
... n
max.
15 ADD-TIF 0.000
C0105 QSP TIF 0.000 0.000 {0.001 s} 999.900 QSP deceleration time
Deceleration time for quick stop (QSP)
(referring to speed variation of 0 ... n
max.
)
C0108 100.00 -199.99 {0.01 %} 199.99
FCODE (gainAOUT)
1 FCODE (GAIN)
Freely assignable code for relative analog
2 FCODE (GAIN)
signals
C0109
-199.99 {0.01 %} 199.99
FCODE (offs.AOUT)
FCODE (OFFSET) 0.00
Freely assignable code for relative analog
FCODE (OFFSET) 0.00
signals
C0114
0
1
HIGH active
LOW active
DIGIN polarity
Terminal polarity
1 DIGIN1 POL 1 X5/E1
2 DIGIN2 POL 1 X5/E2
3 DIGIN3 POL 0 X5/E3
4 DIGIN4 POL 0 X5/E4
5 DIGIN5 POL 0 X5/E5
[C0116] → Selection list 2
Signal configuration FD0-xx
1 FDO-O0 1000 FIXED0
Free digital outputs can onl y be evaluated when
... ... ... ...
being lin
ed wi
hau
oma
ion in
er
aces.
32 FDO-31 1000 FIXED0