Configuration
7-331
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0178 OP TIMER
0
0 {1 s} 4294967295 Elapsed operating time meter
Time when the controller was enabled
C0179 MAINS TIMER
0
0 {1 s} 4294967295 Mains switch-on time meter
Time when the mains was switched on
C0182 TI S-SHAPED 20.00 0.01 {0.01 s} 50.00 NSET
T
i
time of the S-shaped ramp function generator
(determines the shape of the S curve)
Small values small S rounding
Large values large S rounding
C0183 DIAGNOSTICS
0
Drive diagnostics
Indicates fault or status information
If several items of fault or status information
aretobeshown,theinformationwiththe
smallest number is displayed
0 OK No fault
10 Init Initialisation phase
91
92
93
Trip-Set C135
Trip-Set AIF
Trip-Set CAN
102 Trip TRIP active
103 RFG-P-OFF Emergency stop was released
104 IMP Message Message active
105 Power off
Function is not supported
111 BSP C135
112 BSP AIF
Operation inhibited
113 BSP CAN
O
p
e
r
a
t
i
o
n
i
n
h
i
b
i
t
e
d
121 CINH term 28 Controller inhibited via X5/28
122 CINH int 1 DCTRL-CINH1
123 CINH int 2 DCTRL-CINH2
124 CINH C135/STP STOP key at the keypad
125 CINH AIF Controller inhi bi ted via AIF
126 CINH CAN Controller i nhibited via system bus
131 FAIL-QSP Fault reaction
141 Lock mode Restart protection active
142 IMP Power outputs with high resistance
151 QSP ext term QSP via MCTRL-QSP
152 QSP C135/STP QSP via STOP key at the keypad
153 QSP AIF QSP via AIF
154 QSP CAN QSP via system bus
250 Warning Warning active
C0190 NSET ARIT 0 0
1
2
3
4
5
OUT = C46
C46 + C49
C46 - C49
C46 * C49
C46 / C49
C46/(100 - C49)
NSET
Arithmetic block i n the function block NSET
Connects main setpoint C0046 and additional
setpoint C0040
C0195 BRK1 T ACT 99.9 0.0 {0.1 s} 99.9 BRK1
Brake engagement time
Engagement time of the mechanical holding
brake
After the time elapsed under C0195, the status
”mechanical brake closed” is reached
C0196 BRK T RELEASE 0.0 0.0 {0.1 s} 60.0 BRK1
Brake disengagement time
Disengagement time of the mechanic al holding
brake (see technical data of the brake).
After time has elapsed under C0195, the status
”mechanical brake closed” is reached