Configuration
7-342
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
[C0570] IN 1000 FIXED0% Selection list 1 S&H1
Configuration - analog input signal
[C0571] LOAD 1000 FIXED0 Selection list 2 S&H1
Configuration of digital input signal
C0572 (C0570)
0
-199.99 {0.01 %} 199.99
C0573 (C0571)
0
C0577 VP FLD WEAK 3.00 0.00 {0.01 ms] 15.99 Field weakening controller
V
pgain
C0578 TN FLD WEAK 10 2.0 {0.5 ms} 8192.0 Field weakening controller
Adjustment time Tn
C0578 = 8000 ms: Switched off
C0581 MONIT EER 0 0
1
2
3
4
Trip
Message
Warning
Off
Fail-QSP
Monitoring EEr
Configuration - monitoring of external faults
C0582 MONIT OH4 2 2
3
Warning
Off
Monitoring OH4
Configuration - monitoring of heatsink
temperature
C0583 MONIT OH3 0
3
Trip
Off
Monitoring OH3
Configuration - monitoring of ”fixed motor
temperature”
Æ
depending on C0086
C0584 MONIT OH7 2
3
Warning
Off
Monitoring OH7
Configuration - monitoring of ”adjustable motor
temperature”
Æ
depending on C0086
Temperature monitoring via resol ver input
C0585 MONIT OH8 3 0
2
3
Trip
Warning
Off
Monitoring OH8
Configuration - monitoring of ”adjustable motor
temperature”
Tempera ture monitoring via PTC input
C0586 MONIT SD2 0 0
2
3
Trip
Warning
Off
Monitoring SD2
Configuration - resolver monitoring
C0587 MONIT SD3 3 0
2
3
Trip
Warning
Off
Monitoring SD3
Configuration - ”Encoder at X9”
C0588 MONIT H10/H11 3 0
2
3
Trip
Warning
3
Monitoring H10 / H11
Configuration - monitoring of ”temperature
sensors in the controller”
C0589 MONIT P03 2 0
2
3
Trip
Warning
Off
Monitoring P03
Configuration - monitoring of following errors
C0590 MONIT P13 0 0
2
3
Trip
Warning
Off
Monitoring P13
Configuration - monitoring of phase-angle error
C0591 MONIT CE1 3 0
2
3
Trip
Warning
Off
Monitoring CE1
Configuration - monitoring of ”CAN-IN1 fault”
C0592 MONIT CE2 3 0
2
3
Trip
Warning
Off
Monitoring CE2
Configuration - monitoring of ”CAN-IN2 fault”
C0593 MONIT CE3 3 0
2
3
Trip
Warning
Off
Monitoring CE3
Configuration - monitoring of ”CAN-IN3 fault”
C0594 MONIT SD6 0
2
3
Trip
Warning
Off
Monitoring SD6
Configuration - monitoring of ”motor
temperature sensor”
Æ
depending on C0086