Configuration
7-343
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0595 MONIT CE4 3 0
2
3
Trip
Warning
Off
Monitoring CE4
Configuration - monitoring of ”CAN-Bus Off ”
C0596 NMAX LIMIT 5500 0 {1 rpm} 16000 Speed monitoring
Configuration - monitoring of ”machine speed”
C0597 MONIT LP1 3 0
2
3
Trip
Warning
Off
Monitoring LP1
Configuration - monitoring of motor phase
failure
C0598 MONIT SD5 3 0
2
3
Trip
Warning
Off
Monitoring SD5
Configuration - monitoring of ”master current at
X5/1.2 < 2 mA”
C0599 LIMIT LP 1 5.0 1.0 {0.1} 10.0 Current limit LP1
Current limit for motor phase failure monitoring
C0600 FUNCTION 1 0
1
2
3
4
5
OUT = IN1
IN1 + IN2
IN1 - IN2
IN1 * IN2
IN1 / IN2
IN1/(100% - IN2)
ARIT2
Function selection
[C0601] → Selection list 1
ARIT2
1 IN 1000 FIXED0%
Configuration - analog input signals
2 IN 1000 FIXED0%
C0602 (C0602)
0
-199.99 {0.01 %} 199.99
[C0610] → Selection list 1
ADD1
1 IN 1000 FIXED0%
Configuration - analog input signals
2 IN 1000 FIXED0%
3 IN 1000 FIXED0%
C0611
0
-199.99 {0.01 %} 199.99
1 (C0610/1)
2 (C0610/2)
3 (C0610/3)
C0620 DB1 GAIN 1.00 -10.00 {0.01} 10.00 DB1
Gain
C0621 DB1 VALUE 1.00 0.00 {0.01 %} 100.00 DB1
Dead band
[C0622] IN 1000 FIXED0% → Selection list 1 DB1
Configuration - analog input signal
C0623 (C0622)
0
-199.99 {0.01 %} 199.99
C0630 MAX. LIMIT 100.00 -199.99 {0.01 %} 199.99 LIM1
Setting of the upper li mit
C0631 MIN LIMIT -100.0 -199.99 {0.01 %} 199.99 LIM1
Setting of the lower limit
[C0632] IN 1000 FIXED0% →Selection list 1 LIM1
Configuration - analog input signal
C0633 (C0632)
0
-199.99 {0.01 %} 199.99
C0640 DELAY T 20.00 0.01 {0.01 s} 50.00 PT1-1
Setting of the time constant
[C0641] IN 1000 FIXED0% Æ Selection list 1 PT1-1
Configuration - analog input signal
C0642 (C0641)
0
-199.99 {0.01 %} 199.99
C0650 DT1-1 GAIN 1.00 -320.00 {0.01} 320.00 DT1-1
Gain
C0651 DELAY T 1.00 0.005 {0.01 s} 5.000 DT1-1
Time constant
[C0652] IN 1000 FIXED0% → Selection list 1 DT1-1
Configuration - analog input signal