Configuration
7-344
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0653 SENSIBILITY 1 1
2
3
4
5
6
7
15-bit
14-bit
13-bit
12-bit
11-bit
10-bit
9-bit
DT1-1
Input sensitivity
C0654 (C0652)
0
-199.99 {0.01 %} 199.99
C0655 NUMERATOR 1 -32767 {1} 32767 CONV5
Numerator
C0656 DENOMINATOR 1 1 {1} 32767 CONV5
Denominator
[C0657] IN 1000 FIXED0% → Selection list 1 CONV5
Configuration - analog input signal
C0658 (C0657)
0
-199.99 {0.01 %} 199.99
[C0661] IN 1000 FIXED0% → Selection list 1 ABS1
Configuration - analog input signal
C0662 (C0661)
0
-199.99 {0.01 %} 199.99
C0671 RFG1 TIR 0.000 0.000 {0.01 s} 999.900 RFG1
Setting of the acceleration time T
ir
C0672 RFG1 TIF 0.000 0.000 {0.01 s} 999.900 RFG1
Setting of the deceleration time T
if
[C0673] IN 1000 FIXED0% → Selection list 1 RFG1
Configuration - analog input signal
[C0674] SET 1000 FIXED0% → Selection list 1 RFG1
Configuration - analog input signal
[C0675] LOAD 1000 FIXED0 → Selection list 2 RFG1
Configuration of digital input signal
C0676
0
-199.99 {0.01 %} 199.99
1 (C0673)
2 (C0674)
C0677 (C0675)
0
C0680 FUNCTION 6 1
2
3
4
5
6
IN1 = IN 2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMP1
Function selection ( c ompares the inputs IN1
and IN2)
C0681 HYS TERESIS 1.00 0.00 {0.01 %} 100.00 CMP1
Hysteresis
C0682 WINDOW 1.00 0.00 {0.01 %} 100.00 CMP1
Window
[C0683] → Selection list 1
CMP1
1 CMP1-IN1 5001 MCTRL-NACT
Configuration - analog input signals
2 CMP1-IN2 19500 FCODE-17
C0684 (C0683)
0
-199.99 {0.01 %} 199.99
C0685 FUNCTION 1 1
2
3
4
5
6
IN1 = IN2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMP2
Function selection ( c ompares the inputs IN1
and IN2)
C0686 HYS TERESIS 1.00 0.00 {0.01 %} 100.00 CMP2
Hysteresis
C0687 WINDOW 1.00 0.00 {0.01 %} 100.00 CMP2
Window