Configuration
7-377
L
EDSVS9332P-D22 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C1659 FILTER 1 0
1
2
4
8
16
Filter off
Filter 1 ms
Filter 2 ms
Filter 4 ms
Filter 8 ms
Filter 16 ms
SP2
Filters
C1660 ACT.SEL.
0
0 {1} 8 SELPH1
Display of the actual selection
[C1661] S ELPH1-SELECT 1000 FIXED0% → Selection list 1 SELPH1
[C1662] → Selection list 3
SELPH1
1 SELPH1-IN1 1000 FIXED0INC
Input signal configuration
... ... 1000 FIXED0INC
8 SELPH1-IN8 1000 FIXED0INC
C1663 (C1661)
0
-32768 {1} 32767
C1664 (C1662)
0
-2147483648 {1 inc} 147483647
C1665 ACT.SEL.
0
0 {1} 88 SELPH1
Display of the actual selection
[C1666] S ELPH2-SELECT 1000 FIXED0% → Selection list 1 SELPH2
[C1667] → Selection list 3
SELPH2
1 SELPH1-IN1 1000 FIXED0INC
Input signal configuration
... ... 1000 FIXED0INC
8 SELPH1-IN8 1000 FIXED0INC
C1668 (C1666)
0
-32768 {1} 32767
C1669 (C1667)
0
-2147483648 {1 inc} 2147483647
C1670 FUNCTION 1 1
2
3
4
5
6
IN1 = IN2
IN1 > IN2
IN1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMPPH1
Function selection
C1671 HYS TERESIS 50 0 {1 inc} 1073741824 CMPPH1
Hysteresis
C1672 WINDOW 0 0 {1 inc} 1073741824 CMPPH1
Window
[C1673] → Selection list 3
CMPPH1
1 IN 1000 FIXED0INC
Input signal configuration
2 IN 1000 FIXED0INC
C1674
0
-2147483647 {1 inc} 2147483647
CMPPH1
1 IN
2 IN
C1675 FUNCTION 1 1
2
3
4
5
6
IN1 = IN2
IN1 > IN2
IN1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|
CMPPH2
Function selection
C1676 HYS TERESIS 50 0 {1 inc} 1073741824 CMPPH2
Hysteresis
C1677 WINDOW 0 0 {1 inc} 1073741824 CMPPH2
Window
[C1678] → Selection list 3
CMPPH2
1 IN 1000 FIXED0INC
Input signal configuration
2 IN 1000 FIXED0INC
C1679
0
-2147483647 {1 inc} 2147483647
CMPPH2
1 IN
2 IN