Troubleshooting and fault elimination
F ault messages
8-8
L
EDSVS9332P-E EN 3.0
Display RemedyCauseError
Error number
x=0:TRIP
x=1:Message
x=2:Warning
x = 3: FAIL-QSP
P18
1)
x168 Internal limitation
The machine parameters C1202, C1203, C1204 ... can be selected within a defined range of values. In
some cases, the internal range of values may be exceeded. In this event, the values are automatically
limited to the minimum or maximum value. Warning P18 is i ndicated for your information.
C1298 = 1:
The positive position limit in C1223 is outside the
possible display range of
1 (C1223 C1205) 1.07E9 incr
Check machine parameters.
If necessar y, read the current value under
C1220/10 and overwrite the value entered under
C1223.
C1298 = 2:
The negative position limit in C1224 is outside the
possible display range of
1 (C1224 C1205) 1.07E9 incr
Check machine parameters.
If necessar y, read the current value under
C1220/11 and overwrite the value entered under
C1224.
C1298 = 3:
The maximum speed v
max
under C1240 is outside the
possible display range of
1 (C1240 C1205 16384) 2.14E9 incr
or
C1240 / C1204 60 * i 1.5 n
max
Check machine parameters.
If necessar y, read the current value under
C1220/12.
C1220/12 indicates the limited value.
Adapt the value under C1240 to C0011.
v
max
n
max
*v
k
*1/60 *1/i
C1240 C0011 * C1204 C1203 * 1/60 * 1/
C1202
C1298 = 4:
The maximum acceleration a
max
in C1250 is outside
the possible display range of
1 (C1250 C1205 16.384 / 1000) 2.8634E7
incr
Check machine parameters.
If necessar y, read the current value under
C1220/13 and overwrite the value entered under
C1250.
C1298 = 5:
An internal value range has been exceeded for a
speed normalization. Valid range:
1 (C0011 C1207/1 /C1207/2 65536/60000)
32767
Check the entries under C0011, C1207/1.2.
PEr x074 Program fault A fault in the program was detected. Send controller with data (on diskette) to Lenze.
PI x079 Initializing error
A fault was detected during transfer of parameter
set between the controllers
Parameter set does not match controller.
Correct parameter set.
PR0
PR1
PR2
PR3
PR4
x075
x072
x073
x077
x078
Parameter set error Fault when loading a parameter set.
CAUTION:
The factory setting is loaded automatically.
Set the required parameters and store them
under C0003.
For PRO the supply voltage must be switched
off additionally.
Sd2 x082 Resolver error Resolver cable interrupted.
Check the resolver cable for open circuit
Check resolver.
or switch off monitoring (C0586 = 3).
Sd3 x083 Encoder fault at X9/8
Cable interrupted. Check c able for open circuit.
Input X9 PIN 8 not assigned. Assign input X9 PIN 8 with 5V or switch off
monitoring (C0587 = 3).
Sd5 x085 Master current source
defective
Master current at X6/1 X6/2 < 2mA.
Check cable for open circuit.
Check master current sourc e .
Sd6 x086 Se nsor fault Encoder of the motor temperature detection at X7 or
X8 indicates indefinite values.
Check supply cabl e for firm connection.
Switch off monitoring with C0594 = 3 if necessary.