EasyManua.ls Logo

Lenze 9300 - Motor temperature monitoring

Lenze 9300
591 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
4-29
L
EDSVS9332P-B EN 3.0
Supply via external voltage source
++
––
1324
GND1 GND1
X6
X3
1
AIN1 AIN2 AOUT1 AOUT2
2
3
4
7762
63
242R
3.3nF
100k
100k
100k
100k
1
2
3
4
5
6
––
––
9300VEC027
Fig. 4-19 Connection of the analog input signals for external voltage supply
Terminal assignment
Signal type Function
Bold print = Lenze setting (C0005 = 20000)
Level Technical data
X6/1
X6/2
Analog input 1 Differential input of master voltage
not assigned
6
4
2
5
3
1
-10Vto+10V Resolution:
5 mV (11 bits + sign)
Jumper X3
*
Differential input of master current
6
4
2
5
3
1
-20 mA to +20 mA Resolution:
20 µA (10 bits + sign)
Jumper X3
*
X6/3
X6/4
Analog input 2 Difference input of master voltage
not assigned
Jumper X3 has no effect -10Vto+10V Resolution:
5 mV (11 bits + sign)
X6/62 Analog output 1 Monitor 1
Actual speed value
-10Vto+10V;
max. 2 mA
Resolution:
20 mV (9 bits + sign)
X6/63 Analog output 2 Monitor 2
Torque setpoint
-10Vto+10V;
max. 2 mA
Resolution:
20 mV (9 bits + sign)
X6/7 GND1, reference potential for analog signals
* If necessary, remove the AIF module from X1 to reach the jumpers of X3.