Installation
4-30
L
EDSVS9332P-B EN 3.0
Digital frequency input (X9) / Digital frequency output (X10)
Tip!
For the connection to the digital frequency input (X9) or digital frequency output (X10), use
prefabricated Lenze cables. Otherwise, only use cables with twisted pairs and shielded cores (A,
A /B,B/Z,Z) (see connection diagram).
Features of digital frequency output X10 Features of digital frequency input X9
9-pole sub-D socket
Output frequency: 0 - 500 kHz
Current consumption per channel: Max 20mA.
Two-track with inverse 5 V signals (RS422) and zero track
X10 has a different basic setting depending on the selec ted configuration
(C0005)
Factory setting: Encoder simulation of the resolver signal
Load capacity of the parallel connection: Up to three slave drives
Load capacity of the series connection
250 kHz digital master frequency: Up to 22 slave drives
500 kHz digital master frequency: Up to 10 slave drives
LOW-level at X10/8 (enable) i ndicates the initialisation of the master drive
(e. g. if the mains was disconnected). The slave can thus monitor the master.
9-pole sub-D plug
Input frequency: 0 - 500 kHz
Current consumption per channel : Max 6mA.
Two-track with inverse 5 V signals and zero track
Possible input signals:
Incremental encoder with two 5 V complementary signals shifted by 90 °
(TTL encoder)
Encoder simulation of the master
X9/8 is used to monitor the cable or the co nnected controller. For this,
monitoring SD3 must be activated.
LOW-level at X9/8 activates TRIP or warning (SD3)
If the monitoring is not required, this input can be connected to +5V.
B
B
Enable
Lamp
control
GND
GND
Z
Z
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
A
A
X9X10
l = max. 50 m
0.14 26
0.5
0.5
0.14
0.14
26
26
Æ
AWG
20
20
A
A
A
A
mm
2
B
Z
B
B
B
Z
Z
Z
9300VEC019
Fig. 4-20 Connection of digital frequency input (X9) / digital frequency output (X10)
X10 Master X9 Slave c Signal sequence for cw rotation
Assignment of 9-pole sub-D socket (X10)
Assignment of 9 -pole sub-D plug (X9)
Pin 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
Signal B A A +5 V GND1 Z Z EN B B A A +5 V GND1 Z Z LC B
Possible combinations for digital frequency channels X8, X9 and X10
Combination
X8 Encoder input
X9 Digital frequency input
X10 Digital frequency output
Assignment activated Assignment deactivated means
Assignment deactivated X8: C0025 = 10 (feedback with resolver)
X9: Remove function block DFIN from proc essing table and delete link
X10: C0540 = 4 (X10 = X9) or C0540 = 5 (X10 = X8).