Resolver connection (X7)
In all configurations predefined under C0005, a resolver can be used as feedback system. An
adjustment is not necessary.
Note!
Use pre-cut Lenze system cables to connect the resolver.
Please contact Lenze before you use other resolvers.
Features:
2-pole resolver (V = 10 V, f = 4 kHz)
Resolver and resolver cable are monitored for open circuit (fault indication Sd2)
+R EF
-R E F
+C O S
-C O S
+SIN
-S IN
Resolver
1
2
3
4
5
6
7
8
9
+PTC
-P T C
PTC
X7
9 pole S ub-D fem ale connector
C able length m ax. 50 m
0.14 26
0.5 20
mm
2
AW G
Fig. 4-15 Resolver connection
Assignment of the female connector (X7)
Pin 1 2 3 4 5 6 7 8 9
Signal +Ref -Ref GND1 +COS -COS +SIN -SIN +PTC
(
^