Commissioning
5-17
BA9300POS EN 2.3
Description of the input template
Click on the Programming button in the Basic settings” dialog box.
12345
6
7
8
Fig. 5-13 Dialog box for entering the positioning data
Field
Function Description
1 Dialog box for a program set
(PS)
All necessary positioning profile parameters for a PS are entered as well as possible branches
to further PS.
2, 3 Parameter field Click on field. A dialog box (3) for selecting a parameter is opened.
4, 5, 6 Selection field A parameter is selected. Click on desired parameter. For variable tables (VT) you can describe
the table items. For this, click on Input” (5). A dialog box (6) for entering a parameter is
opened.
6 Dialog box Dialog box for entering a parameter in the variable table
7 Input field Input of the desired parameter
8 Comment on the parameter You can write a comment to the parameter, e.g. for which function it is required.