Function library
DCTRL
Axis module status
12
300
EDBCSXS064 EN 4.0
The status bits 8 ... 11 in C0150 display the binary−coded device status of the axis module:
Status bit 11 Status bit 10 Status bit 9 Status bit 8 Description
000 0 Initialisation after connecting the
supply voltage
0 0 0 1 Switch−on inhibit / restart
protection active (C0142 = 0)
0 0 1 1 Controller inhibited
0 1 1 0 Controller enabled
0 1 1 1 A monitoring function returns a
"message".
1 0 0 0 A monitoring function returns a
"TRIP".
1 0 1 0 A monitoring function returns a
"FAIL−QSP".
0 = FALSE 1 = TRUE