Appendix
Code table
13
384
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0362 Sync cycle
Time interval between 2 sync
telegrams via the X4 CAN bus
interface or EMF2192IB EtherCAT
communication module at X1 AIF
interface
Read only
179
1 {1 ms} 30
C0363 Sync correct. 1
CAN sync correction increment
180
1 0.2 ms/ms
2 0.4 ms/ms
3 0.6 ms/ms
4 0.8 ms/ms
5 1.0 ms/ms
C0365 DIS:CAN
active
Input signal CAN active
Only display
0 CAN not active
1 CAN active
C0366 Sync Response 1
CAN sync response for interface
X4 (CAN)
The value "1" should always be
set!
181
0 No response
1 Response
C0367 Sync Rx ID 128
CAN sync receipt ID for CAN bus
interface X4
180
1 {1} 256
C0368 Sync Tx Id 128
CAN Sync transmission ID for
CAN bus interface X4
444
179
1 {1} 256
C0369 SyNc Tx time 0
CAN sync transmission cycle for
CAN bus interface X4
A sync telegram with the
identifier of C0368 is sent with
the cycle time set.
ECSxP: The setting is effected
automatically depending on
C4062!
180
0 {1 ms} 65000 0 = switched off
[C0370] SDO gateway 0
Activate address
gateway/remote
parameterisation
l C0370 ¹ 0: All code
write/read accesses are
redirected to the CAN node
with the CAN node address
set here.
l The corresponding code is
accessed via parameter data
channel 1 of the target device.
l C0370 = 0: remote
parameterisation is
deactivated
190
0 {1} 63