Appendix
Code table
13
385
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0371 Gateway Ch. 1
Selection of the gateway channel
190
0 CAN Use CAN bus interface X4
1 CAN−AUX Use CAN bus interface X14
C0381 HeartProdTim
e
0
Heartbeat (slave):
HeartbeatProducerTime
l Time interval for sending the
heartbeat message
l Only relevant for setting
C0352 = 3.
0 {1 ms} 65535
C0382 GuardTime 0
Node Guarding (slave):
NodeGuardTime
l Time interval of the status
inquiry of the master
l Only relevant for setting
C0352 = 4.
184
0 {1 ms} 65535
C0383 LifeTimeFact 0
Node Guarding (slave):
NodeLifeTime factor
l Factor for the monitoring
time of NodeLifeTime
l NodeLifeTime = C0383 x
C0382 (NodeGuardTime)
l Only relevant for setting
C0352 = 4.
184
0 {1} 255
C0384 Err
NodeGuard
3
Node Guarding (slave)
l Response for the occurrence
of a NodeGuard−Event
l Only relevant for setting
C0352 = 4.
184
0 TRIP
1 Message
2 Warning
3 Off
4 FAIL−QSP
C0400 DIS: AnalogIn
Signal at the analog input
Read only
266
−199.99 {0.01 %} 199.99
C0414 DIS: ResQual.
Resolver modulation
Quality of the resolver excitation
amplitude set under C0416
(recommendation: 0.5 ... 1.2;
ideal 1.0)
104
0.00 {0.01} 1,60