EasyManua.ls Logo

Lenze ECSES Series - Page 395

Lenze ECSES Series
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
Code table
13
395
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0856 Analog process data input words
are indicated decimally on the
AIF interface (AIF1_IN)
100.00% = 16384
Read only
248
1 AIF1 IN words −199.99 {0.01 %} 199.99 Input word 1
2 AIF1 IN words Input word 2
3 AIF1 IN words Input word 3
C0857 AIF1 IN phi
32 bits of phase information on
the AIF interface (AIF1_IN)
Read only
248
−2147483648 {1} 2147483647
C0858 Analog process data output
words are indicated decimally on
the AIF interface (AIF1_OUT)
100.00% = 16384
Read only
1 AIF1 OUT
words
−199.99 {0.01 %} 199.99 Output word 1
2 AIF1 OUT
words
Output word 2
3 AIF1 OUT
words
Output word 3
C0859 AIF1 OUT phi
32−bit phase information at the
AIF interface (AIF1_OUT)
Only display
−2147483648 {1} 2147483647
C0863 Digital process data input words
for CAN bus interface X4
Hexadecimal value is bit−coded.
Read only
448
273
0000 {hex} FFFF
1 CAN IN bits Bit 0 ... Bit15 CAN1_IN: Process data input
word 1
2 CAN IN bits Bit 16 ... Bit 31 CAN1_IN: Process data input
word 2
3 CAN IN bits Bit 0 ... Bit15 CAN2_IN: Process data input
word 1
4 CAN IN bits Bit 16 ... Bit 31 CAN2_IN: Process data input
word 2
5 CAN IN bits Bit 0 ... Bit15 CAN3_IN: Process data input
word 1
6 CAN IN bits Bit 16 ... Bit 31 CAN3_IN: Process data input
word 2