Code table
13
407
EDBCSXS064 EN 4.0
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C2466 Sync Response 1
CAN sync response for interface
X14 (CAN−AUX)
The value "1" should always be
set!
0 No response
1 Response
C2467 Sync Rx ID 128
CAN−AUX sync receipt ID for CAN
bus interface X14
180
1 {1} 256
C2468 Sync Tx ID 128
CAN−AUX Sync−transmission ID
for CAN bus interface X14
444
181
1 {1} 256
C2469 Sync Tx time 0
CAN−AUX sync transmission cycle
for CAN bus interface X14
A sync telegram with the
identifier of C2468 is sent with
the set cycle time.
179
176
0 {1 ms} 65000 0 = switched off
C2470 ParWrite 0
CANaux channel used by
L_ParWrite/L_ParRead
(byComChannel = 11)
190
0 Unused PDO channel free for
reconfiguration
(CANaux1...3_IN/CANaux1...3_OUT)
1 Parameter data channel 2
C2481 MONIT CE11 3
Fault response − monitoring
CANaux1_IN error
"CommErrCANauxIN1" (CE11)
198
0 TRIP
2 Warning
3 Off
C2482 MONIT CE12 3
Fault response − monitoring
CANaux2_IN error
"CommErrCANauxIN2" (CE12)
198
0 TRIP
2 Warning
3 Off
C2483 MONIT CE13 3
Fault response − monitoring
CANaux3_IN error
"CommErrCANauxIN3" (CE13)
198
0 TRIP
2 Warning
3 Off
C2484 MONIT CE14 3
Fault response − "system bus
(CAN−AUX) off" monitoring at
CAN bus interface X14
"BusOffState" (CE14)
198
0 TRIP
2 Warning
3 Off