Optimising the operating behaviour
Oscillation damping
6.11
6.11.2

6.11−3
EDSVF9383V EN 7.1−04/2012
6.11.2 Oscillation damping
Suppressing no−load oscillations in case of:
Æ’ Drives with different rated power of controller and motor, e. g. when
operating with high switching frequency and the power derating
involved.
ƒ Operation of higher−pole motors.
ƒ Operation of three−phase AC drives > 10 kW.
Compensation of resonances in the drive kit:
Æ’ Certain asynchronous motors may show this behaviour above
1
/
3
of
the rated speed (
1
/
3
× n
n
). This may result in an unstable operation
(current and speed variations).
Codes for parameter setting
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0234 damp value 20 −100 {1 %} 100 Influence of the oscillation
damping, function block MCTRL
l Minimising a tendency to
oscillation of the drive
l Influences the tendency to
oscillation of the drive
l When C0025 >1 and C0006 = 1,
C0234 is set to 0

8.2−25

8.2−40
C0235 damping 2 1 {1 ms} 600 Filter time of the oscillation
damping, function block MCTRL
l Filter time for the internal
signal for oscillation damping

8.2−25

8.2−40
C0236 damp limit 1.0 0.0 {0.1 Hz} 20.0 Limit value of oscillation damping,
function block MCTRL
l Limit value for the internal
signal of oscillation damping
Description

Table of Contents

Other manuals for Lenze EVS9321-Ex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVS9321-Ex and is the answer not in the manual?

Lenze EVS9321-Ex Specifications

General IconGeneral
BrandLenze
ModelEVS9321-Ex
CategoryController
LanguageEnglish

Related product manuals